 Data Sheet October 14, 2009
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
Features
RoHS Compliant
n n n n n
Compatible with RoHS EU Directive 200295/EC Compatible in Pb- free or SnPb reflow environment Nonisolated output High efficiency: 86% typical Small size and low profile: 63.5 mm x 5.6 mm x 14 mm (2.5 in x 0.22 in x 0.55 in) Remote On/Off Output overcurrent protection Output voltage adjustment Overtemperature protection UL* 60950 Recognized, CSA C22.2 No. 60950-00 Certified, and VDE 0805 (IEC60950, 3rd edition) Licensed Meets FCC classA radiated limits
n n n n
Applications
n n n
n
Distributed Power Architectures Communication Equipment Computer Equipment
n
Options
n n
Tight Tolerance output -40 C operation
Description www..com
The NH020-Series Power SIPs are nonisolated dc-dc converters that operate over an input voltage range of 4.5 Vdc to 5.5 Vdc and provide a precisely regulated dc output. The SIPs have a maximum output current rating of 6 A at a typical full-load efficiency of 86%. Standard features include remote on/off and output voltage adjustment.
* UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association.
Document Name: PDF Name:DS00-128EPS (Replaces DS00-127EPS)
Data Sheet October 14, 2009 Absolute Maximum Ratings
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliabiltiy.
Parameter Input Voltage: Continuous Operating Ambient Temperature* Storage Temperature On/Off Terminal Voltage
-1
Symbol VIN TQ31 Tstg Von/off
Min 0 -40/0 -55 --
Max 7.0 115 125 6.0
Unit Vdc C C Vdc
* Forced convection--1.5 ms (300 lfm) minimum. Higher ambient temperatures are possible with increased airflow and/or decreased power output. See the Thermal Considerations section for more details. The -40 C operation is optional. See Ordering Information section.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter Operating Input Voltage Maximum Input Current (VI = 0 to VI,max; IO = IO,max) Inrush Transient Input Reflected-Ripple Current (5 Hz to 20 MHz; 500nH source impedance;See Figure 14) Input Ripple Rejection (100 - 120Hz)
Symbol VI II,max i 2t
Min 4.5 -- --
Typ 5.0
Max 5.5 6.1
Unit Vdc A A 2s mAp-p dB
-- 625 60
1
CAUTION: This power module is not internally fused. An input line fuse must always be used. This power SIP can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow fuse with a maximum rating of 10 A (see Safety Considerations section). To aid in the proper fuse selection for the given application, information on inrush energy and maximum dc input current is provided. Refer to the fuse manufacturer's data for further information.
www..com
Lineage Power
2
Data Sheet October 14, 2009 Electrical Specifications (continued)
Parameter Output Voltage Set Point (VI = 5.0 V; IO = IO, max; TA = 25 C)
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
Device NH020M NH020M2 NH020Y NH020Y2 NH020G NH020F NH020F2 NH020M NH020M2 NH020Y NH020Y2 NH020G NH020F NH020F2 All M Y F, G All
Symbol VO, set VO, set VO, set VO, set VO, set VO, set VO, set VO VO VO VO VO VO VO -- -- -- -- --
Min 1.46 1.485 1.75 1.782 2.43 3.18 3.27 1.43 1.455 1.716 1.745 2.39 3.16 3.24 -- -- -- -- --
Typ 1.5 1.5 1.8 1.8 2.5 3.3 3.3 -- -- -- -- -- -- -- 0.1 0.4 0.3 0.1 --
Max 1.54 1.515 1.85 1.818 2.57 3.39 3.33 1.57 1.545 1.883 1.855 2.61 3.44 3.36 0.4 0.6 0.5 0.3 17
Unit Vdc Vdc Vdc Vdc Vdc Vdc Vdc Vdc Vdc Vdc Vdc Vdc Vdc Vdc %VO %VO %VO %VO mV
Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until end of life.)
Output Regulation: Line (VI = 4.5 V to 5.5 V) Load (IO = 0 to IO, max)
Temperature (TA = 0 C to 55 C) Output Ripple and Noise Voltage (See Figures 7--9 and 15.): RMS Peak-to-peak (5 Hz to 20 MHz) External Load Capacitance (electrolytic) Output Current (Forced convection, 1.5 ms-1 (300 lfm)) Output Current-limit Inception (VO = 90% of VO, set; see Feature Descriptions section.) Efficiency (VI = 5.0 V; IO = IO, max; TA = 25 C; see Figures 3--6 and 16.) Switching Frequency Dynamic Response (IO/t = 1 A/10 s, VI = 5.0 V, TA = 25 C; see Figures 10 and 11.): Load Change from IO = 0% to 100% of IO, max: Peak Deviation Settling Time (VO < 10% peak deviation) Load Change from IO = 100% to 0% of IO, max: Peak Deviation Settling Time (VO < 10% peak deviation)
F, G, M Y All All All All
-- -- -- -- IO IO
-- -- -- 0 0 --
-- -- -- -- -- 350
25 30 100 10,000 6 --
mVrms mVrms mVp-p F A %IO, max
NH020M NH020Y NH020G NH020F All
h h h h --
70 73 79 84 --
72 75 82 86 500
-- -- -- -- --
% % % % kHz
All All All All
-- -- -- --
-- -- -- --
80 200 80 200
-- -- -- --
mV s mV s
General Specifications
www..com
Weight Parameter Min -- Typ 1,400,000 -- 7(0.25) Max Unit Hours g (oz.)
Calculated MTBF (IO = 80% of IO, max TA = 25 C)
Lineage Power
3
Data Sheet October 14, 2009 Feature Specifications
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information.
Parameter Remote On/Off Signal Interface (VI = VI,min to VI, max; open collector pnp or Compatible, Von/off signal referenced to GND. See Figure 20 and Feature Descriptions section) Logic Low (ON/OFF pin open--Module On) Ion/off = 0.0 A Von/off = 0.3 V Logic High (VON/OFF > 2.8 V)--Module Off Ion/off = 10 mA Von/off = 5.5 V Turn-on Time (IO = 80% of IO, max; VO within 1% of steady state; see Figure 12) Output Voltage Set-point Adjustment Range Device Symbol Min Typ Max Unit
All All All All All NH020M NH020Y NH020G NH020F All
Von/off Ion/off Von/off Ion/off -- Vtrim Vtrim Vtrim Vtrim TQ31
-0.7
0.3 50 6.0 10 5.0 150 120 110 110 --
V A V mA ms %VO, nom %VO, nom C
1.5 100 100 90 84 -- -- -- -- -- 125
Overtemperature Protection (shutdown)
www..com
Lineage Power
4
Data Sheet October 14, 2009
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
Characteristic Curves
The following figures provide typical characteristics curves (TA = 25 C).
Figure 1. Typical Input Characteristics at 6 A output
current.
Figure 4.
Typical Efficiency for NH020Y.
Figure 2. Typical Output Characteristics.
Figure 5.
Typical Efficiency for NH020A0G.
www..com
Figure 3.
Typical Efficiency for NH020M .
Figure 6.
Typical Efficiency for NH020F.
Lineage Power
5
Data Sheet October 14, 2009 Characteristic Curves
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
The following figures provide typical characteristics curves at room temperature (TA = 25 C)
Figure 7. Typical Output Ripple Voltage fo NH020M
(6A Output Current).
Figure 9.
Typical Output Ripple Voltage for NH020F,G (6A Output Current).
www..com
Figure 8. Typical Output Ripple Voltage for NH020Y
(6A Output Current). Figure 10. Typical Transient response to Step load change from 0% to 100% of I0,max at 5V Input .
Lineage Power
6
Data Sheet October 14, 2009 Characteristic Curves
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
The following figures provide typical characteristics curves at room temperature (TA = 25 C)
Figure 11. Typical Transient response to Step load
change from 100% to 0% of I0,max at 5V Input .(Waveform Averaged to remove ripple) Figure 13. Typical start -up Transient with remote on/off at 5V Input and 6A output.
www..com
Figure 12. Typical start up Transient at 5V input and 6A
output.
Lineage Power
7
Data Sheet October 14, 2009 Test Configurations
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W Design Considerations
Input Source Impedance
The power SIP should be connected to a low ac- impedance input source. Highly inductive source impedances can affect the stability of the SIP. Adding external capacitance close to the input pins of the SIP can reduce the ac impedance and ensure system stability. The minimum recommended input capacitance (C1) is a 100 F electrolytic capacitor (see Figures 17 and 19).
T O O SC ILLO SC O PE
L VI ( + ) 500 nH C S 220 F BAT T ER Y ESR < 0.1 * @ 20 C , 100 k H z VI ( -)
Note: Measure input reflected ripple current with a simulated source inductance (LTEST) of 500nH. Capacitor CS offsets possible battery impedance. Measure current as shown above.
Figure 14. Input Reflected Ripple Current Test Setup.
Figure 17. Setup with External Capacitor to Reduce
Input Ripple Voltage . To reduce the amount of ripple current fed back to the input supply (input reflected-ripple current), an external input filter can be added. Up to 10 F of ceramic capacitance (C2) may be externally connected to the input of the SIP, provided the source inductance (LSOURCE) is less than 1 H (see Figure 17). To further reduce the input reflected-ripple current, a filter inductor (LFILTER) can be connected between the supply and the external input capacitors (see Figure 18). As mentioned above, a 100 F electrolytic capacitor (C1) should be added across the input of the SIP to ensure stability of the unit. The electrolytic capacitor should be selected for ESR and RMS current ratings to ensure safe operation in the case of a fault condition. Refer to Figure 19 for the appropriate electrolytic capacitor ratings. When using a tantalum input capacitor, take care not to exceed device power rating because of the capacitor's failure mechanism (for example, a short circuit). The filter inductor should be rated to handle the maximum power SIP input current of 6.1 Adc. If the amount of input reflected-ripple current is unacceptable with an external L-C filter, more capacitance may be added across the input supply to form a C-L-C filter. For best results, the filter components should be mounted close to the power SIP.
Note: Scope measurements should be made using a BNC socket, with a 47 F tantalum capacitor .Position the load between 51 mm and 76 mm (2 in and 3 in) from the module
Figure 15. Peak-to-Peak Output Ripple Measurement Test Setup.
Note: All voltage measurements to be taken at the module terminals, as shown above. If sockets are used then Kelvin connections are required at the module terminals to avoid www..com measurement errors due to socket contact resistance.
Figure 16. Output Voltage and Efficiency Test Setup.
[ V O(+) - V O(-) ] x I O = ------------------------------------------------ x 100 [ V I(+) - V I(-) ] x I I
Lineage Power
8
Data Sheet October 14, 2009 Design Considerations (continued)
Input Source Impedance (continued)
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
Figure 18. Setup with External Input Filter to Reduce Input Reflected-Ripple Current and Ensure Stability.
Figure 19. Electrolytic Capacitor ESR and RMS Current Rating Data.
Safety Considerations
For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL60950, CSA C22.2 No. 60950-00, and VDE 0805:2001-12 (IEC60950, 3rd Ed). For the converter output to be considered meeting the requirements of safety extra-low voltage (SELV),the input www..comSELV requirements. must meet The power module has ELV (extra-low voltage) outputs when all inputs are ELV. The input to these units is to be provided with a maximum 10A normal-blow fuse in the unearthed lead. If an input electrolytic capacitor is to be used, it should be selected using the design information found in the Design Considerations section. Lineage Power
9
Data Sheet October 14, 2009 Feature Descriptions
Remote On/Off
To turn the power SIP on and off, the user must supply a switch to control the voltage at the on/off terminal (Von/off). The switch can be an open collector pnp transistor connected between the on/off terminal and the VI terminal or its equivalent (see Figure 20). During a logic low when the ON/OFF pin is open, the power SIP is on and the maximum Von/off generated by the power SIP is 0.3 V. The maximum allowable leakage current of the switch when Von/off = 0.3 V and VI = 5.5 V (Vswitch = 5.2 V) is 50 A. During a logic high, when Von/off = 2.8 V to 5.5 V, the power SIP is off and the maximum Ion/off is 10 mA. The switch should maintain a logic high while sourcing 10 mA. If not using the remote on/off feature, leave the ON/OFF pin open. The SIP has internal capacitance to reduce noise at the ON/ OFF pin. Additional capacitance is not generally needed and may degrade the start-up characteristics of the SIP. CAUTION: Never ground the on/off terminal. Grounding the on/off terminal disables an important safety feature and may damage the SIP or the customer system.
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
18.23 Rtrim-down = ----------------------------- - 15 k VO - VO , adj
For the G (2.5 VO) SIP:
6.975 Rtrim-down = ------------------------------------ - 15 k 2.498 - VO , adj
Note: Output voltages below 2.5 V cannot be trimmed down. The test results for these configurations are displayed in Figures 21 and 22.
Figure 21. NH020G Rtrim-down Test Results .
Figure 20. Remote On/Off Implementation.
Output Voltage Set-Point Adjustment (Trim)
Output voltage set-point adjustment allows the output voltage set point to be increased or decreased by connecting an external resistor between the TRIM pin and either the VO pin (decrease output voltage) or GND pin (increase output voltwww..com age). The trim range for the NH020F is +10%, -16%. The trim range for the NH020G is 10% of VO, nom. The trim range for SIPs that produce less than 2.5 VO is +20%, -0%. Connecting an external resistor (Rtrim-down) between the TRIM and VO pin decreases the output voltage set point as defined in the following equation. For the F (3.3 VO) SIP: Lineage Power Figure 22. NH020F Rtrim-down Test Results . Connecting an external resistor (Rtrim-up) between the TRIM and GND pins increases the output voltage set point to VO, adj as defined in the following equation:
28 Rtrim-up = ----------------------------- - 1 k VO , adj - VO
The test results for this configuration are displayed in Figures 23--26. Leave the TRIM pin open if not using that feature. 10
Data Sheet October 14, 2009 Feature Descriptions (continued) Output Voltage Set-Point Adjustment (Trim) (continued)
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
Figure 26. NH020F Rtrim-up Test Results . Overcurrent Protection Figure 23. NH020M Rtrim-up Test Results.
To provide protection in a fault condition, the unit is equipped with internal overcurrent protection. The unit operates normally once the fault condition is removed. The power module will supply up to 350% of rated current for less than 1.25 seconds before it enters thermal shutdown.
Overtemperature Protection
To provide additional protection in a fault condition, the unit is equipped with a nonlatched thermal shutdown circuit. The shutdown circuit engages when Q1 or Q2 exceeds approximately 110 C. The unit attempts to restart when Q1 or Q2 cool down and cycles on and off while the fault condition exists. Recovery from shutdown is accomplished when the cause of the overtemperature condition is removed.
Figure 24. NH020Y Rtrim-up Test Results.
www..com
Figure 25. NH020G Rtrim-up Test Results . Lineage Power 11
Data Sheet October 14, 2009 Thermal Considerations
To predict the approximate cooling needed for the SIP, determine the power dissipated as heat by the unit for the particular application. Figures 29--32 show typical heat dissipation for the SIP over a range of output currents.
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
Figure 29. NH020M Power Dissipation vs. Output
current.
Note: Dimensions are in millimeters and (inches).
Figure 27. Thermal Test Setup.
Proper cooling can be verified by measuring the power SIP's temperature at lead 7 of Q31 as shown in Figure 28. Figure 30. NH020Y Power Dissipation vs. Output Current.
Figure 28. Temperature Measurement Location. The temperature at this location should not exceed 115 C. The output power of the SIP should not exceed the rated power for the SIP as listed in the Ordering Information table.
Convection Requirements for Cooling
To predict the approximate cooling needed for the SIP, determine the power www..com dissipated as heat by the unit for the particular application. Figures 29--32 show typical heat dissipation for the SIP over a range of output currents. Figure 31. NH020G Power Dissipation vs. Output Current.
Lineage Power
12
Data Sheet October 14, 2009
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
Figure 32. NH020F Power Dissipation vs. Output Current. With the known heat dissipation and a given local ambient temperature, the minimum airflow can be chosen from the derating curves in Figure 33.
Figure 33. Power Derating vs. Local Ambient
Temperature and Air Velocity.
For example, if the unit dissipates 2.0 W of heat, the minimum airflow in an 80 C environment is 1.0 m/s (200 ft./min.). Keep in mind that these derating curves are approximations of the ambient temperatures and airflows required to keep the power SIP temperature below its maximum rating. Once www..com the SIP is assembled in the actual system, the SIP's temperature should be checked as shown in Figure 28 to ensure it does not exceed 115 C.
Layout Considerations
Copper paths must not be routed between pins 2 and 3 and pins 7 and 8. Lineage Power 13
Data Sheet October 14, 2009 Through-Hole Lead-Free Soldering Information
The RoHS-compliant through-hole products use the SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant components. They are designed to be processed through single or dual wave soldering machines. The pins have an RoHScompliant finish that is compatible with both Pb and Pb-free wave soldering processes. A maximum preheat rate of 3C/s is suggested. The wave preheat process should be such that the temperature of the power module board is kept below 210C. For Pb solder, the recommended pot temperature is 260C, while the Pb-free solder pot is 270C max. Not all RoHS-compliant through-hole products can be processed with paste-through-hole Pb or Pb-free reflow process. If additional information is needed, please consult with your Tyco Electronics Power System representative for more details.
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
Post Solder Cleaning and Drying Considerations
Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to Tyco Electronics Board Mounted Power Modules: Soldering and Cleaning Application Note (AP01-056EPS).
Solder Ball and Cleanliness Requirements
The open frame (no case or potting) power module will meet the solder ball requirements per J-STD-001B. These requirements state that solder balls must neither be loose nor violate the power module minimum electrical spacing. The cleanliness designator of the open frame power module is C00 (per J specification).
www..com
Lineage Power
14
Data Sheet October 14, 2009 Outline Diagram for Through-Hole Module
Dimensions are in millimeters and (inches). Tolerances:
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
x.x mm 0.5 mm (x.xx in. 0.02 in.) [unless otherwise indicated] x.xx mm 0.25 mm (x.xxx in. 0.010 in.)
Front View
Side View
Pin 1 2 3 4 5 6 7 8 9
Function VO VO VO GND GND VI VI TRIM ON/OFF
www..com
Lineage Power
15
Data Sheet October 14, 2009 Recommended Hole Pattern
Component-side footprint. Dimensions are in millimeters and (inches).
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
Note: No copper should be placed between pins 2 and 3 and pins 7 and 8.
www..com
Lineage Power
16
Data Sheet October 14, 2009 Ordering Information
NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
Please contact your Tyco Electronics' Sales Representative for pricing, availability and optional features. Table 1. Device Codes Input Voltage 5V 5V 5V 5V 5V 5V 5V Output Voltage 1.5 V 1.8 V 2.5 V 3.3 V 3.3V 2.5 V 1.8 V Output Current 9W 10.8 W 15 W 20 W 20W 15 W 10.8 W Device Code NH020M NH020Y NH020G NH020F NH020FZ NH020GZ NH020Y2Z Comcodes 107870065 TBD 107917114 107221145 CC109114121 CC109102753 CC109102761
Optional features can be ordered using the suffixes shown below. The suffixes follow the last letter of the Product Code and are placed in descending alphanumerical order. Table 2. Device Options Option Tight tolerance output (not available on the NH020G) -40 C operation RoHS Compliant Suffix 2 5 -Z
A sia-Pacific Head qu art ers T el: +65 6 41 6 4283 Eu ro pe, M id dle-East an d Afric a He ad qu arters T el: +49 898 780 672 80 Ind ia Head qu arters T el: +91 8 0 28411633
World W ide Headq u arters Lin eag e Po wer Co rp oratio n 601 Shiloh Road, Plano, TX 75074, U SA +1-800-526-7819 www..com .: +1- 97 2-244 -9428) (Outs id e U .S.A www.line ag ep ower.co m e-m ail: tech sup port1@ lin ea gep ower.co m
Lineage Power reserves the right to make changes to the produc t(s) or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any s uc h pr oduct(s ) or information. Lineage Power DC-DC products are protected under various patents. Information on these patents is available at www.lineagepower.com/patents. (c) 2009 Lineage Power Corpor ation, (Plano, Texas ) All International Rights Res er ved.
October 2009
PDF Name:DS00-128EPS (Replaces DS00-127EPS)


▲Up To Search▲   

 
Price & Availability of NH020

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X